[Processing stability, removal of pressurized flotation devices, etc.] Improvement of wastewater treatment facility at chicken meat primary processing plant.

Change the existing aeration device of the treatment tank to an Aqua Blaster to enhance processing capacity, allowing treatment to be conducted without the use of a pressurized flotation device.

Due to the increase in wastewater volume associated with the factory expansion, the aeration device of the existing treatment tank was changed to an Aqua Blaster to enhance processing capacity. By installing Aqua Blasters in the adjustment tank and aeration tank, we successfully accepted a load increase of 10-20% without increasing the tank size. Furthermore, it has become possible to carry out treatment without using a pressurized flotation device.

  • Wastewater/wastewater treatment equipment
  • Water treatment equipment
  • Other water treatment equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Improvement of wastewater treatment facilities at food complexes for processing stability and reduction of electricity costs.

The removal rate of BOD is 80%, and the removal rate of normal hexane extractable substances is 82%, showing significant improvement! Even after more than 8 and a half years, it maintains a no-maintenance state.

Before the installation of the Aqua Blaster, a large amount of oil and grease scum accumulated in just one day, leading to the formation of oil balls. Hydrogen sulfide was generated to the extent that it corroded surrounding equipment. The oil balls on the water surface and those that sank to the bottom were regularly manually retrieved and disposed of as industrial waste. As a result of installing the Aqua Blaster, the BOD removal rate improved significantly to 80%, and the removal rate of n-hexane extractable substances improved to 82%. Even after more than eight and a half years, there has been no need for removal or dredging work, and a no-maintenance state has continued. The dramatic improvement in water quality has led to waterfowl visiting the sedimentation tank every year without fail. Below are the results from the installation in 2012 to 2020 over eight years: - With a 6-hour retention time in the adjustment tank, BOD and n-hex were cut by over 80%. - The floating oil and grease and settled sludge that had been generated in the adjustment tank have not been removed even once in eight years. - Hydrogen sulfide levels decreased from 100 ppm to 0 ppm. - At the outlet of aeration tank 1, the Setouchi regulations are being met. - The sludge conversion rate for BOD was reduced from 35% to 25%. - The sedimentation tank has remained stable, attracting ducks. - Excess sludge has drastically decreased, and the odor from its steam drying is no longer a concern.

  • Wastewater/wastewater treatment equipment
  • Water treatment equipment
  • Other water treatment equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration